Overview of the Fluke 179 Multimeter

The Fluke 179 True RMS Multimeter is a high-precision, battery-powered device with a 6000-count, 3․75-digit display․ It offers CAT III and CAT IV safety compliance, making it suitable for various industrial and electrical applications․ Part of the Fluke 170 Series, it is known for its durability, accuracy, and versatility in measuring voltage, current, and resistance․ The meter includes advanced features like MIN/MAX/AVG recording mode and a bar graph display for better readability․ It is an essential tool for professionals requiring reliable and accurate measurements in demanding environments․

The Fluke 179 True RMS Multimeter is a portable, high-accuracy measurement tool designed for professionals․ It provides precise measurements of DC/AC voltage, current, and resistance, with true RMS capabilities for accurate readings․ Featuring a 6000-count display and bar graph, it ensures clear results․ This multimeter is ideal for industrial, electrical, and field service applications, offering reliability and durability in demanding environments․

1․2 Key Features and Specifications

The Fluke 179 True RMS Multimeter features a 6000-count, 3․75-digit LCD display with a bar graph for precise readings․ It measures DC voltage (0․1mV resolution), AC voltage (0․1mV), current (10A), and resistance (0․1Ω)․ CAT III 1000V and CAT IV 600V safety ratings ensure protection․ It includes MIN/MAX/AVG recording, auto-ranging, and manual range selection․ The meter is powered by a 9V battery and comes with test leads, an 80BK temperature probe, and a user manual․

1․3 Models 175, 177, and 179: A Comparison

The Fluke 175, 177, and 179 are True RMS multimeters with a 6000-count display․ All models share CAT III and CAT IV safety ratings, manual/auto-ranging, and basic measurement capabilities․ The 177 adds MIN/MAX/AVG recording, while the 179 includes all features of the 177 plus an 80BK temperature probe․ The 175 is the base model with essential functions․ Each model caters to different user needs, from basic to advanced applications․

Safety Precautions and Information

Ensure compliance with CAT III and CAT IV standards․ Avoid damaged test leads or non-operating meters․ Use proper terminals, switch positions, and ranges for measurements․ Service the meter if unsure to prevent shock or damage․

2․1 General Safety Precautions

Always use undamaged test leads and ensure the multimeter is in proper working condition․ Avoid operating in hazardous environments or with wet hands․ Regularly inspect the device for damage․ Follow all safety guidelines outlined in the manual to prevent electrical shock or injury․ Ensure correct terminal connections and range selections for measurements․ Proper usage extends the meter’s lifespan and ensures accurate readings․ Adhere to all warnings and cautions provided in the user manual․

2․2 CAT III and CAT IV Compliance

The Fluke 179 multimeter meets CAT III and CAT IV safety standards, ensuring protection against arc faults and high-voltage transients․ CAT III applies to measurements up to 600V in industrial environments, while CAT IV is suitable for 600V in direct connection to the electrical source․ This compliance ensures the device’s robustness and safety for professionals working in challenging electrical conditions, reducing risks of damage or injury during measurements․ Always verify the category rating for your specific application․

2․3 Warning and Caution Symbols

The Fluke 179 multimeter features warning and caution symbols to ensure safe operation․ These symbols, such as the lightning bolt for high voltage and the explosion hazard symbol, alert users to potential dangers․ It is crucial to understand and adhere to these warnings to prevent injuries, damage to the device, or voiding the warranty․ Always refer to the manual for symbol explanations and safety guidelines before performing measurements․

Installation and Setup

Unpack the Fluke 179 multimeter, verify all accessories, and install the battery․ Familiarize yourself with the controls and settings before first use for optimal performance․

3․1 Unpacking and Inventory

When unpacking the Fluke 179 multimeter, ensure all components are included, such as the multimeter itself, test leads, the 80BK temperature probe, a 9V battery, and the user manual․ Verify each item for damage and familiarize yourself with their purposes․ The battery is pre-installed, and the test leads are ready for use․ Additionally, check for any user-replaceable parts and accessories mentioned in the manual to ensure everything is accounted for before initial use․

3․2 Accessories Included

The Fluke 179 multimeter comes with essential accessories, including high-quality test leads, a 9V alkaline battery, and the 80BK temperature probe․ The kit also includes a detailed user manual for operation guidance․ Additional Fluke-recommended accessories, such as extended test lead sets or carry cases, may be available separately to enhance functionality and convenience for various measurement tasks․

3․3 Replacing the Battery and Fuses

To replace the battery, turn off the multimeter and remove the old 9V battery․ Install a new alkaline battery, ensuring correct polarity․ For fuses, use only Fluke-approved replacements to avoid damage․ Always disconnect the meter from any circuit before performing these replacements․ Proper disposal of old batteries and fuses is recommended․ Refer to the user manual for detailed instructions․ Advanced users may require additional tools or professional assistance for fuse replacement․

Making Basic Measurements

The Fluke 179 accurately measures DC and AC voltage, current, and resistance with high precision, ensuring reliable and accurate readings for various industrial applications․

4․1 DC Voltage Measurement

The Fluke 179 accurately measures DC voltage with a resolution of 0․1 mV․ To measure DC voltage, select the DC voltage range, connect the test leads to the correct terminals (COM and VΩ), and read the display․ Ensure the meter is set to the appropriate range for precise measurements․ The 6000-count display provides high resolution, making it ideal for precise DC voltage readings in industrial and electrical applications․

4․2 AC Voltage Measurement

The Fluke 179 True RMS Multimeter accurately measures AC voltage with a resolution of 0․1 mV․ To measure AC voltage, select the AC voltage range, connect the test leads to the appropriate terminals (COM and VΩ), and ensure the multimeter is set to AC mode․ The True RMS capability ensures accurate measurements for non-sinusoidal waveforms․ Always verify the range selection to avoid meter damage and ensure precise readings․

4․3 Current and Resistance Measurements

For current measurements, use the 10A or 10mA terminals, selecting the appropriate range for accurate readings․ Resistance measurements are taken using the COM and VΩ terminals, with a resolution of 0․1 ohms․ Always ensure the multimeter is set to the correct mode (current or resistance) and select the appropriate range for precise results․ High sensitivity ensures accurate measurements, while safety features protect against overloads․ Avoid using damaged test leads to maintain measurement integrity․

Operating Modes

The Fluke 179 offers Manual Range Selection, Auto Range Functionality, and MIN/MAX/AVG Recording Mode․ These modes ensure precise measurements, adaptability, and data recording for various applications․

5․1 Manual Range Selection

The Fluke 179 allows users to manually select measurement ranges for voltage, current, and resistance․ This feature ensures optimal resolution by choosing the most suitable range for specific measurements․ Manual range selection is activated by pressing the appropriate button, providing precise control for accurate readings in various applications, enhancing measurement reliability and flexibility for professionals requiring detailed data capture․ This mode is ideal for situations where fixed ranges are preferable to automatic adjustments, ensuring consistent and reliable results․

5․2 Auto Range Functionality

The Fluke 179’s Auto Range functionality automatically selects the best measurement range for optimal resolution; This feature streamlines operations by eliminating manual adjustments, ensuring quick and accurate readings․ The meter adjusts its range dynamically based on input signals, providing reliable results across various measurement scenarios․ Auto Range is particularly useful for field technicians needing efficient and precise data capture without manual intervention, enhancing productivity and reducing measurement errors in diverse applications․

5․3 MIN/MAX/AVG Recording Mode

The MIN/MAX/AVG mode on the Fluke 179 captures the minimum, maximum, and average values of measured inputs․ This feature is ideal for monitoring fluctuating signals, such as voltage or current, over time․ It provides a running average for trend analysis and helps detect transient changes․ The mode is particularly useful in troubleshooting applications, offering insights into signal stability and patterns․ Real-time updates ensure accurate and reliable data capture, enhancing diagnostic capabilities in industrial and electrical environments․

Troubleshooting Common Issues

Troubleshooting the Fluke 179 involves identifying errors like inaccurate measurements or battery issues․ Check test leads, ensure proper calibration, and verify fuse conditions․ Addressing these common problems ensures accurate and reliable operation․

6․1 Identifying and Resolving Measurement Errors

Identify measurement errors by inspecting test leads for damage and ensuring secure connections․ Verify that the correct range is selected for the measured value․ If problems continue, check calibration and adjust as needed․ Replace blown fuses to restore functionality․ Regular firmware updates and proper maintenance routines help prevent errors and ensure accurate, reliable measurements every time․

6․2 Common Error Messages and Solutions

The Fluke 179 may display error messages like “OL” (overrange) or “0․L” (open circuit)․ Check connections and ensure the correct range is selected․ Blown fuses or flat batteries can also cause issues․ Replace fuses with the correct type and charge or replace the battery․ Consult the user manual for specific solutions and ensure proper calibration for accurate measurements․ Addressing these errors promptly ensures reliable operation and extends the meter’s lifespan․ Always refer to the manual for detailed troubleshooting guidance․

6․3 When to Service the Meter

Service the Fluke 179 if it shows persistent errors, inaccurate readings, or physical damage․ If self-troubleshooting fails, contact Fluke Support for professional repair․ Regular calibration and maintenance are essential for accuracy․ Damaged test leads or worn-out fuses also indicate the need for servicing․ Always use authorized Fluke service centers to ensure compliance with warranty and safety standards, maintaining the meter’s reliability and performance over time․

Calibration and Maintenance

Regular calibration ensures accuracy, while maintenance involves cleaning, battery checks, and firmware updates․ Follow Fluke’s guidelines to maintain performance and extend the meter’s lifespan effectively․

7․1 Calibration Information

Calibration ensures the Fluke 179 Multimeter maintains its accuracy․ It is recommended to follow Fluke’s calibration procedures, as outlined in the user manual, to verify and adjust measurements․ The meter supports true RMS measurements for DC and AC voltage, current, and resistance․ Calibration should be performed periodically, especially if the meter is used in demanding environments․ Refer to the calibration information manual or supplementary guides for detailed instructions and specifications to ensure optimal performance and compliance with industry standards․

7․2 Routine Maintenance Tips

Regular maintenance ensures the Fluke 179 Multimeter performs optimally․ Always use the correct test leads and avoid damaged ones to prevent measurement errors․ Clean the terminals and connectors to maintain proper conductivity․ Replace the battery and fuses as specified in the manual to ensure reliability․ Store the meter in a dry, cool environment to protect it from damage; Refer to the user manual for detailed maintenance procedures to extend the lifespan and accuracy of your device․

7․3 Updating Firmware (if applicable)

Updating your Fluke 179 multimeter’s firmware ensures you have the latest features and performance enhancements․ Begin by visiting the official Fluke website and navigating to the support or downloads section․ Locate the specific firmware update for your Fluke 179 model and download it․ Before proceeding, check your meter’s current firmware version in the settings or “About” section to confirm compatibility․ Connect your multimeter to your computer using the appropriate interface, such as USB, and use the provided software to transfer the firmware․ Ensure the battery is fully charged or use an external power source to prevent interruptions․ Follow the step-by-step instructions provided by Fluke carefully to avoid any issues․ After completing the update, restart your multimeter to apply the changes․ If you encounter any problems, refer to the troubleshooting guide or contact Fluke support for assistance․

Accessories and Compatible Products

The Fluke 179 includes TL76 test leads and an 80BK temperature probe, with additional accessories like test leads and probes available for enhanced functionality and accuracy․

8․1 Test Leads and Probes

The Fluke 179 comes with TL76 test leads, designed for precision and durability․ These leads are insulated for safety and feature shrouded tips to prevent accidental contact․ Additional probes, such as the 80BK temperature probe, expand measurement capabilities, allowing users to measure temperature alongside electrical parameters․ All accessories are built to Fluke’s high standards, ensuring reliability and accuracy in various applications․

8․2 Temperature Probe (80BK)

The Fluke 80BK temperature probe is included with the 179 model, enabling precise temperature measurements․ This probe enhances the multimeter’s functionality, allowing users to measure temperature alongside electrical parameters․ Designed for accuracy and durability, it is an essential accessory for industrial applications․ The 80BK probe is part of the standard kit, ensuring users have everything needed for comprehensive measurements right out of the box․

8․3 Other Fluke-Recommended Accessories

Fluke offers a range of accessories to enhance the functionality of the 179 multimeter․ The VPS 40 voltage probe set is ideal for high-voltage applications, while the Fluke 61 infrared thermometer complements thermal measurements․ Additional accessories include carrying cases, test lead extensions, and firmware update tools․ These products are designed to optimize performance and versatility, ensuring users have the right tools for diverse measurement tasks․ Visit Fluke’s website for the full list of compatible accessories․

Warranty and Support

Fluke provides a limited warranty covering defects in materials and workmanship for a specified period․ Contact Fluke support for assistance, and access online resources for manuals and updates․

9․1 Limited Warranty Details

The Fluke 179 is backed by a limited warranty covering defects in materials and workmanship․ The warranty period varies by region, typically covering the product for a set number of years from the date of purchase․ It does not cover damage caused by misuse, neglect, or normal wear and tear․ For specific terms and conditions, refer to the official Fluke website or contact their customer support team directly․

9․2 Contacting Fluke Support

For assistance with the Fluke 179, contact Fluke support through their official website or regional customer service centers․ Visit http://us․fluke․com for contact details, technical support, and repair services․ Ensure to have your product serial number ready for efficient assistance․ Fluke’s dedicated team provides troubleshooting, repair options, and warranty-related inquiries, ensuring optimal support for your multimeter needs․

9․3 Online Resources and Manuals

Fluke provides comprehensive online resources for the 179 multimeter, including user manuals, data sheets, and quick start guides․ Visit http://us․fluke․com to access these documents․ The website also offers troubleshooting tips, firmware updates, and detailed specifications․ Additionally, the 80BK Temperature Probe manual and other accessory guides are available for download, ensuring users have all necessary information for optimal functionality and maintenance of their Fluke 179 multimeter․

Leave a Reply